Specification
System
Modular IVD laboratory analytical system combines Immunology, Biochemistry, Electrolyte and Sample handling modules together, full expansion and flexible recombination to satisfy all different requirements in the laboratory.
Sample Processing Module
● Loading 280 samples at one time
● 4 channels, high speed loading
● STAT Channel
Electrolyte Module
● 1000 test/hour
● Continuous loading reagent during operation
● Double channels, high speed
● RFID tag for reagent information, Instant recognition
Biochemistry Module
● 1600 tests/hour
● 90 reagent positions, continuous loading
● 2 independent paddle stirrers, polished with Nano material, throughly mixing
● Water bath, constant and accurate temperature control: 37℃±0.1℃
● Holographic Concavity flat field grating, rear spectroscopy technology
● Wavelength range 340nm-800nm, detect 16 wavelengths simultaneously
Immunoassay Module
● Non-enzyme involved flash chemiluminescence
● Nano magnetic microbeads for separation
● 280 tests/hour
● 25 reagent positions, continuous loading
● RFID tag for reagent information, Instant recognition
● More than 100 parameters
● 2 point calibration to adjust master curve, maximum calibration stability: 4 weeks
Combination
● Powerful and flexible combination options, maximum 4 biochemistry or 4 Immunoassay modules can be integrated together.
Modular IVD laboratory analytical system combines Immunology, Biochemistry, Electrolyte and Sample handling modules together, full expansion and flexible recombination to satisfy all different requirements in the laboratory.
Sample Processing Module
● Loading 280 samples at one time
● 4 channels, high speed loading
● STAT Channel
Electrolyte Module
● 1000 test/hour
● Continuous loading reagent during operation
● Double channels, high speed
● RFID tag for reagent information, Instant recognition
Biochemistry Module
● 1600 tests/hour
● 90 reagent positions, continuous loading
● 2 independent paddle stirrers, polished with Nano material, throughly mixing
● Water bath, constant and accurate temperature control: 37℃±0.1℃
● Holographic Concavity flat field grating, rear spectroscopy technology
● Wavelength range 340nm-800nm, detect 16 wavelengths simultaneously
Immunoassay Module
● Non-enzyme involved flash chemiluminescence
● Nano magnetic microbeads for separation
● 280 tests/hour
● 25 reagent positions, continuous loading
● RFID tag for reagent information, Instant recognition
● More than 100 parameters
● 2 point calibration to adjust master curve, maximum calibration stability: 4 weeks
Combination
● Powerful and flexible combination options, maximum 4 biochemistry or 4 Immunoassay modules can be integrated together.
Feature:
Modular IVD laboratory analytical system combines Immunology, Biochemistry, Electrolyte and Sample handling modules together, full expansion and flexible recombination to satisfy all different requirements in the laboratory.